    Although it’s an absolute pain in the arse in certain scenarios. Surge protectors essentially present as a leak to earth any time they do their job, so my mandatory RCCBs on every circuit turn minor mains fluctuations into permanent outages.

    I really need to see if I can legally run one circuit that isn’t RCD protected for my homelab…

      • timochka@lemmy.zip
        link
        fedilink
        arrow-up
        2
        ·
        2 days ago

        You understand that the RCD is (mandatorily) in the electrical distribution panel where it hands off to the utility supply right?

        • ammonium@lemmy.world
          link
          fedilink
          arrow-up
          1
          ·
          2 days ago

          I don’t know all the details. Are you sure you’re literally not allowed to place anything before the RCD? Technically SPD then RCD makes the most sense to me, so it seems strange to me that it wouldn’t be allowed, but I couldn’t find any clear answer.

          • timochka@lemmy.zip
            link
            fedilink
            arrow-up
            1
            ·
            2 days ago

            I have a suspicion that the kind of surge protector rating it’s reasonable to fit to the main electrical input for a building is unlikely to actually trigger on the small surges that the surge protector in a UPS will, and you will still get earth-leakage trips on the RCDs with UPSs downstream of them.

            Having one radial (for the computer rack) NOT protected by an RCD seems like a cheaper and more reliable solution, but I confess it’s not bubbled to the top of my to-do list yet to get a sparky involved for advice.